Shopping cart (0)  
Your Cart is Empty Now.
View My Cart
   
View Mobile Site
+65 6589 8909 /
+1 408 800 5917
sales@mycro.sg
UV Flood Curing System
UV Flood Curing System
IntelliRay - Full-Featured UV Flood Curing System The IntelliRay is a compact microprocessor-controlled UV flood curing system. All system components are integrated into a small lamp head which can be easily mounted on the optional Rayven benchtop curing chamber or anywhere on a factory floor, with virtually no cabling or remote power boxes required. Just mount the head, connect the AC line cord, and start timed exposure curing! The system contains an integrated retractable shade type shutter, which allows for repeatable exposure timing, and shields the user from UV rays. The system’s LCD display and digital keypad make programming and monitoring of curing operations a snap. The long life arc lamp and parabolic reflector illuminate an 8 x 6 inch curing area with evenly distributed UV light. The arc lamp is powered by the state of the art UV Power-Plus Lamp Driver. For a larger version of this system, see the IntelliRay Quad. The head features a convenient carrying handle and sliding height adjustment bracket. • The IntelliRay is available in 400W or higher intensity 600W version. • 175 mW/cm2 Intensity @ 3"• 8" x 6" curing area• User control of time & intensity / Remote control & reporting via PC or PLC• Integrated exposure shutter• Solid-state / Constant power• Optional shielded benchtop curing chamber SpecificationsSystem TypeParabolic Flood Curing SystemPart #UV0338UV0832Lamp Power400W600WInput Voltage100-120 / 200-240 VAC ±10% (auto-ranging)Input Current (Max)7.0/3.5 Amps10.0/5.0 AmpsIrradiance@ 3"115 mW/cm2 UVA, typical175 mW/cm2 UVA, typicalCuring Area8" x 6"Weight13 lbsSize (L x W x H)11” x 10” x 9” System TimersDuration of curing is controlled by a 1 to 9999 second or hour exposure timer that actuates the shutter. The exposure timer also has a user controlled manual mode, and a mode for use in long exposure applications such as artificial aging or solar panel testing. Lamp Intensity ControlThe system has a user adjustable intensity level. This feature provides the flexibility of choosing appropriate curing intensity for sensitive materials. Time, intensity as well as all other settings can be password protected. Standby ModeThe unit automatically reduces lamp power when the shutter is closed. This reduces excessive heat and therefore increases life of system components, without the need to power down. Status IndicatorsFour front panel LEDs are provided: Lamp ready, system in standby mode, shutter open, and system alarm. External Logic Signal InterfaceThe system can be remotely monitored and controlled using logic signals available at a 15 pin D-sub connector on the unit’s rear panel. The digital logic functions allow high speed control of the IntelliRay for applications requiring a direct interface with machine controllers or PLCs. Remote Control via PC Serial PortThe system can also be remotely controlled via a RS232 / RS485 serial port. A Windows™ compatible graphical interface program allows all system functions to be exercised (see photo), and with RS485, multiple units can be networked. Foot Pedal ControlAn optional shutter control foot pedal is available for applications requiring hands-free operation. The pedal can be used in conjunction with the system's exposure timer, or in a manual mode in which the shutter remains open as long as the pedal is pressed. Lamp Power RegulationThe system’s switch mode power supply maintains constant lamp power regardless of variations in AC line input or lamp voltages. The result is repeatable curing times throughout the life of the lamp. Auto-Range AC Line InputThe Auto-Ranging 90-132 / 180-265 VAC line input makes the Uvitron IntelliRay easy to use in any country, with no wiring changes or voltage select switching required. Forced Air CoolingA baffled fan cooling system with removable filter channels cooling air appropriately to all components to ensure high system reliability. Best-in-Class Lamp LifeThe IntelliRay systems now have enhanced lamp life which rivals even microwave and LED systems, significantly lowering operating and maintenance costs. Typical lamp life (intensity versus time) charts are available for 400W and 600W IntelliRay systems.
UV Ozone Systems
UV Ozone Systems
UV Ozone Systems Instruments that Work Easy-to-use, high quality, reliable and affordable ▶ The PSD Series (PSD-UV)▶ The PSD Pro Series (PSDP-UV) ▶ The PSD Pro Heated Series (PSDP-UVT)The PSD and PSDP systems are similar in performance and dimensions, but vary in controller capability, upgradability and heated stage options. Selecting the proper system for your application• atomic cleaning of surfaces• polymer bonding• organic molecule stripping• release of trapped inorganic molecules• microfluidic fabrication• micro and nano-patterning• UV curing• chemical surface modification• surface sterilization• surface oxidation• metal bonding prep... and more Sample Applications In addition to the above uses, Novascan's PSD series instruments are often used for scanning probe microscopy applications. Our instruments can be used to clean common oily films and trapped inorganic materials from AFM tips, SPM standards and surfaces. Treatment can also be used to alter surface hydrophobicity, assist in tip and surface chemical modifications, oxidize and harden tips helping to maintain tip geometry while scanning, and sharpen tips for improved lateral resolution.  Novascan instruments are used in nanotechnology, chemistry, biology, optics, electronics, semiconductor, and other scientific laboratories around the world. The PSD Series publication list continues to grow. Sample SubstratesSilicon/Silicon Nitride/Borosilicate Glass/Silcon dioxide/Mica/Quartz/Metals/Ceramics/Sapphire/Gallium Arsenide/Polymers such as PDSMOther Materials Contaminated glass laboratory slide  Contaminated glass laboratory slide after 10 minutes of PSD treatment Glass laboratory slide, decontaminated after 20 minutes of PSD treatment
UV Ozone Cleaner
UV Ozone Cleaner
Ultra-Clean Surfaces in MinutesProduce near-atomically clean surfaces without causing damage to the sampleWithin minutes, the Ossila UV Ozone Cleaner is capable of removing contamination from the surface of substrates and samples, providing ultraclean surfaces. Using a high-power UV light source to generate ozone and break down organic surface contaminants, the procedure can produce near-atomically clean surfaces without causing any damage to your sample. Volatile compounds created from surface contaminants will quickly evaporate, leaving the sample ready for the next part of your experiment.The our UV ozone cleaner is an extremely versatile piece of equipment. It is able to treat a wide range of materials for a number of different applications and will soon be an essential part of your lab.High Intensity UV LampThe Ossila UV Ozone Cleaner houses a series of high intensity, low pressure synthetic quartz mercury vapour discharge lamps. By utilizing the emission at 185 nm and 254 nm, ozone is generated. The presence of ozone and UV light allows for the removal of organic material. The high intensity output gives results quickly and facilitates a large cleaning area.Large Cleaning AreaDespite the small footprint of the unit itself, there is a large illumination area. The tray can accommodate wafers with up to 153 mm diameter (6 inch), which allows for the cleaning of a wide array of samples, including:Microscope slides、6-Inch wafer、AFM tips、Diced substrates、Petri dishes and more.The maximum recommended substrate thickness is 12 mm.Simple to Use InterfaceThe bright LCD display and tactile keypad provide a simple interface. With the easy-to-use built-in software, it only takes a short time to start cleaning your samples.Using the buttons on the front of the unit, it is easy to control the cleaning time. The built-in software continuously monitors the temperature inside the system; the panel can show temperature readings for the tray, UV lamp, and electronics. This makes it easy to make sure that delicate samples do not overheat.UV Light SpecificationsDimensions and WeightMaterials and FinishUser InterfaceSafety FeaturesPower SupplyCertification and Standards
IntelliRay Quad
IntelliRay Quad
System timers: Duration of curing is controlled by a 1–9,999 second or hour exposure timer that actuates the shutter. The exposure timer also has a user-controlled manual mode and a mode for use in long exposure applications such as artificial aging or solar panel testing.Lamp intensity control: The system has a user-adjustable intensity level. This feature provides the flexibility of choosing appropriate curing intensity for sensitive materials. You can password protect time, intensity and all other settings.Standby mode: The unit automatically reduces lamp power when the shutter is closed. This reduces excessive heat and therefore increases the life of system components without the need to power down.Status indicators: Four front panel LEDs are provided: lamp ready, system-in-standby mode, shutter open and system alarm.External logic signal interface: The system can be monitored and controlled remotely using digital logic signals available at a 15 pin D-sub connector on the unit’s rear panel. The digital logic functions allow high-speed control of the IntelliRay for applications requiring a direct interface with machine controllers or PLCs.Remote Control via PC serial port: The system can also be controlled remotely via an RS232 / RS485 serial port. A Windows™ compatible graphical interface program allows all system functions to be exercised (see photo), and with RS485, multiple units can be networked.Lamp power regulation: The system’s switch mode power supply maintains constant lamp power regardless of variations in AC line input or lamp voltages. The result is repeatable curing times throughout the life of the lamp.Forced air cooling: Variable speed cooling fans with removable filters direct air to critical system components, ensuring cool operation and high system reliability.Best-in- class lamp life: The enhanced lamp life of the system rivals even microwave and LED systems, significantly lowering operating and maintenance costs.System Type:Parabolic Flood Curing SystemPart #:UV2591-HLamp Power:2400W (4 x 600W)Input Voltage:200–240 VAC ±10%Input Current (Max):16AIrradiance at 4″:110 mW/cm2 UVA, typicalCuring Area:16 x 12″Weight:26.6 lbs.Size (L x W x H):17.45 x 23 x 7.75”
PortaRay
PortaRay
Fully integrated lamp head: The hand-held lamp head is fully self-contained and includes an extra long-life 400W or 600W arc lamp, which emits evenly distributed UVA, UVB or visible light. The unit’s arc lamp is powered by the state-of-the-art UV Power-Plus Lamp Driver. The typical lamp life is 2,000 hours. The lamp reflector is available as a parabolic 5 x 5″ type for uniform, larger area curing, or optionally as a focused (circular) 5 x 3″ type for higher intensity curing of smaller areas.Lamp power regulation: The system’s switch mode power supply maintains constant lamp power regardless of variations in AC line input or lamp voltages. This regulation provides for repeatable curing times and longer lamp life.Standby mode: The unit features a standby mode rocker switch, which reduces lamp power by one-half. This mode can be used to reduce heat and stray UV light output while the system is not in use.Two AC line input versions: The system is available in 90–132VAC and 180–265VAC input voltage ranges that make it compatible for use worldwide.Forced air cooling: An integrated cooling fan in the lamp head ensures cool operation and high system reliability.SpecificationsSystem Type:Portable Flood Curing SystemPart #s:UV2270UV2267Lamp Power:400W600WReflector Options:Parabolic 5 x 5″ (large area curing)Focused: 5 x 3″ (high intensity curing)Accessory Box & Headrest Options:Headrest lamp head onlyClosed headrestMax Chamber Part Size:4.25 x 4.25 x 2”In drawer type headrest
SunRay
SunRay
Lamp power regulation: The system’s switch mode power supply maintains constant lamp power regardless of variations in AC line input or lamp voltages. This regulation provides for repeatable curing times and longer lamp life.Standby mode: The unit features a standby mode rocker switch, which reduces lamp power when the system is idling. This mode can be used to reduce heat and stray UV light output while the system is not in use.Auto-range AC line input: The auto-ranging 90–132 / 180–265VAC line input makes the SunRay easy to use in any country, with no wiring changes or voltage select switching required.Elapsed hour meter: A front panel hour meter tracks lamp age, allowing for consistent lamp replacement scheduling.External logic signal interface: The system can be remotely monitored and controlled using logic signals available at a 15 pin D-sub connector on the unit’s rear panel. The following signal types are available:Lamp standby control input for variable PWM control or for minimizing of lamp intensity during idle periods.Hour meter reset input for zeroing hours after lamp replacement.24VDC at 1A output for powering external fans, relays, solenoids or motors.Forced air cooling: Baffled fan cooling directs air to critical system components, ensuring cool operation and high system reliability.SpecificationsSystem TypeParabolic Flood Curing SystemPart #UV0446UV0830Lamp Power400W600WInput Voltage100–120 / 200–240 VAC ±10% (auto-ranging)Input Current (Max)7.0/3.5 Amps10.0/5.0 AmpsIrradiance @ 3"115 mW/cm2 UVA, typical175 mW/cm2 UVA, typicaCuring Area8 x 6"Weight11 lbs.Size (L x W x H)11 x 10 x 9”
Rayven Quad
Rayven Quad
Integrated sensors: The Rayven Quad contains an integrated sensor for monitoring chamber temperature when used with the IntelliRay Quad. The included automatic door interlock causes the IntelliRay Quad’s shutter to close and shield the user when the door is opened.External control interface: Dual rear panel D-sub connectors allow pass-through of IntelliRay control signals for use with a PC, PLC, shutter control foot pedal, external interlock, etc.SpecificationsPart #UV2875-HCoolingForced air w/ louvers, channeled from lamp headInterconnect CableDual 15 position D-sub (Male/Female, 1.25'), includedDimensions (H x W x D)Inside12.5 x 22.0 x 16.4”w/ adjustable shelfOutside14.1 x 24.2 x 19.5”D = 20.65 w/ door handleWeight24.0 lbsw/out lamp headCure DistanceShelf Positions4”, 6”, 8”, 10”,3", 5", 7", 9"Bottom of lamp to shelfDistance to Floor12.5”Bottom of lamp to floor
Light-shielding UV curing chamber
Light-shielding UV curing chamber
Door interlock: The Rayven includes a door interlock that, when used with the IntelliRay system, automatically causes the unit’s shutter to close when the door is opened. When used with the SkyRay system, the LEDs automatically turn off when the door is opened.External control interface: Dual rear panel D-sub connectors allow pass-through of IntelliRay, SunRay and SkyRay control signals for use with a PC, PLC, shutter control foot pedal, external interlock, etc.SpecificationsPart #UV1080CoolingForced air w/ louvers, channeled from lamp headInterconnect CableDual 15 position D-sub (Male/Female, 1.25'), includedDimensions (H x W x D)Inside9 x 9 x 10.4”w/ adjustable shelfOutside11.8 x 11.6 x 12.1”D = 13.3 w/ door handleWeight (lbs)9 lbs.w/out lamp headCure Distance (IntelliRay / SunRay)Shelf Positions1.75”, 3.5”, 5.25”, 7.0”Bottom of lamp to shelfDistance to Floor9”Bottom of lamp to floorCure Distance (SkyRay)Shelf Positions.75", 2.5", and 4.25"Bottom of lamp to shelfDistance to Floor6.250”Bottom of lamp to floor
SkyBeam
SkyBeam
Four irradiation channels: Four independent irradiation channels each offer a 0–999.9 second exposure timer and 10–100% power adjustment range. Each channel’s UV light spot size can be adjusted by replacing the optical lens at the end of its light guide, and the service life of each irradiation channel is independently recorded.External control interface: The system can be remotely monitored and controlled using isolated logic signals available at the rear panel terminals. The digital logic functions allow high-speed control of the SkyBeam for applications requiring a direct interface with machine controllers or PLCs. Control signals include LEDs on/off and a safety interlock that disables LEDs for operator protection. Monitoring signals include system ready, LEDs on and system alarm. An RS232 port is also provided for serial communication with PCs and PLCs.Long-life flexible light guides: The cable of the UV LED light guides is a two-meter flexible robot cable, tested to over 10 million bending cycles. Four wavelengths are available, including 365, 385, 395 and 405nm.Cool operation: Both convection cooling and fan cooling UV LED light guides are offered. The fan cooling type has better heat dissipation and is suggested for continuous operation. The UV LED light guide has a built-in temperature sensor that monitors the temperature and prevents the light guide from overheating. The aluminum controller housing is fully sealed to prevent contamination and ensure long system life.Security key switch: The system comes with a security key switch that prevents operators from making unauthorized changes to the approved running parameters.SpecificationsSystem TypeLED SpotPart #UV3979Input Voltage100–240VAC ±10%Input Current (Max)1.0 Amps at 120V,0.5 Amps at 240VIrradianceFrom 900–14,000 mW/cm2 UVA (lens dependent)Curing AreaFrom 3 mm–15mm spot size (lens dependent)Size (H x W x D), Weight140 mm x 92 mm x 160 mm, 3.25 lbs.
UV Conveyor 40 Plus
UV Conveyor 40 Plus
Adjustable lamp height and end chute: Foldaway end covers provide quick access to height adjustment pins, which provide perfectly repeatable settings of lamp head to belt distance. An adjustable position end chute guides accumulating cured parts as they exit the conveyor.Removable lamp heads: The system’s dual lamp heads can be easily removed for bulb replacement and maintenance. They can also be moved quickly from the conveyor to optional low cost shielded mounting stands. This feature allows for offline engineering process testing, and maximum equipment utilization.Dual spectrum capable: The UV Conveyor 40 Plus dual lamp heads offer the unique curing advantage of mixing any of its four available lamp spectrum types. For instance, the UV conveyor’s first lamp head can be fitted with a UVA type whose longer wavelengths penetrate more effectively, providing deeper UV curing.   The second lamp can be a UVB lamp for sealing the surface, preventing oxygen from diffusing and causing surface tackiness. This optimizes adhesive reaction speed without the need for an expensive nitrogen purge or the delays of pulse curing.Full UV shielding: The conveyor light chamber is totally enclosed, shielding the operator and others nearby from any light exposure during the UV curing process. The light chamber entrance and exit are protected by sliding tinted acrylic doors with extended hoods.Digital speed readout & E-stop switch: A digital rate meter accurately displays the conveyor’s belt speed in feet per minute, allowing for repeatable curing time settings. An emergency stop switch allows quick and safe shutdown of conveyor and lamps.Exhaust port: The light chamber has a top-mounted 3″ diameter port for optional venting to facility exhaust systems.Optional mounting stands: The system may be configured with extruded aluminum height adjustable mounting stands. The stands have unique swivel support brackets that allow them to support inclined conveyors, as well as provide angular transitions between continuous conveyors.Other options: The light chamber can be outfitted with various reflector and lamp spectrum options. Other conveyor lengths are available as special order. Many accessories are also available for configuring the conveyor system into an automated assembly center: Over-belt counter tops, under-belt storage bins, walk-thru gate sections, 90º-turn wheels, end-to-end or end-to-side belt transition plates, product end stops, half stops, guide rails, photoelectric sensors, convenience outlets, remote foot pedals, etc.UV Conveyor 40 Plus - Specs & DimensionsSystem Type:Conveyor, variable speedPart #:UV3028–120M (120 VAC),UV3028–240M (240 VAC, required for dual SkyRay 800 or sidecure configurations)Input Voltage:100–120 or 200–240 VAC ±10% rangesInput Current (Max):20A at 120V, 15A at 240VCuring Width:6" exposure width, 9" max part widthBelt L x W:54 x 9”Belt Speed:0.5–25’ / minLamp Height, Adjustable:1.2–6.7”, 0.5” stepsSize:54 x 14 x 16”Weight:63.2 lbsLamp Type2 SunRay 400 UVA (arc)2 SunRay 600 UVA (arc)2 SkyRay 800 365nm (LED)2 PortaRay 400 Sidecure UVA (arc)Lamp Power400W600W800W400WIrradiance(3” distance)115 mW/cm²175 mW/cm²1000 mW/cm²95 mW/cm² @ 5”Lamp base to belt centerCuring Energy (0.5–25’ / min)294–14,683mJ/cm²447–22,344 mJ/cm²2600–116,000mJ/cm²175–8,500mJ/cm² (per side)Exposure Time3.2–160 sec.3.2–160 sec.2.0–100 sec.2.0–100 sec.
SunSpot 2
SunSpot 2
Cool light output: A dichroic-coated reflector reflects only the useable UV wavelengths of light through the light guide. The harmful high-temperature infrared is diverted away from the material being cured. A secondary in-line filter is used to further reduce heat for extremely sensitive applications.Lamp intensity control: The SunSpot 2 has a user-adjustable front-panel locking intensity control, with a 35–100% combined power adjustment range. This provides the flexibility to choose appropriate curing intensity for sensitive materials and to regulate intensity at a given level as the lamp ages.Timer-controlled shutter: An accurate 99-second, foot-pedal-initiated exposure timer and shutter free the operator’s hands for other tasks. At any time, a second press of the pedal immediately stops the exposure and closes the shutter. The timer can also be switched from timed to manual mode for operator control of curing duration, with the shutter remaining open only while the pedal is depressed.Front panel indicators: A lamp ignited indicator illuminates when the lamp is lit, and a lamp ready LED signals when warm-up is complete. A resettable front panel hour meter tracks lamp age, allowing for consistent lamp replacement scheduling.Light guide handle lock: The light guide receptacle includes a handle locking thumbscrew that prevents accidental guide pull-out and provides for easy multi-pole guide balancing.External logic signal interface: The system can be remotely monitored and controlled using logic signals available at a 9 pin D-sub connector on the unit’s rear panel. The digital logic functions allow high-speed control of the SunSpot 2 for applications requiring a direct interface with machine controllers or PLCs. Control signals include lamp off, shutter open and hour meter reset. Monitoring signals include lamp ignited and lamp ready.Lamp power regulation: The SunSpot’s switch-mode power supply maintains constant lamp power regardless of variations in AC line input or lamp voltages. This tight regulation results in stable light output, repeatable cure times and long lamp life.Lamp auto-dim: The system automatically reduces lamp power to a low standby level when the shutter closes, instantly returning to full intensity when the shutter reopens. This auto dimming extends lamp life and reduces power consumption and unnecessary heating.Quick-change lamp: The system’s side lamp access panel is easily removed by loosening thumbscrews, making the lamp / reflector module replacement possible in as little as one minute.Safety interlocks: Two unique safety interlocks provide maximum protection during operation and maintenance procedures. The first automatically forces the shutter closed if the light guide is removed, preventing operator exposure to high-intensity light. The second immediately removes system AC input power when the lamp access panel is opened, protecting the operator from high voltages or high-intensity light present behind the panel.Forced air cooling: The infrared regulated dual-fan cooling system directs air to critical system components, ensuring cool operation, maximum lamp life and system reliability.SpecificationsSystem TypeFocused spot w/ light guidePart #UV1853 (120VAC),UV2132 (240VAC)Lamp Power200WInput Voltage100–120 or 200–240VAC ±10% rangesInput Current (Max)4.7 Amps at 120V,2.5 Amps at 240VIrradiance18,000 mW/cm2 UVACuring Area1.5"/3.0" spot size at 1.5"/3.0" distanceSize (H x W x D), Weight4.05 x 8.64 x 10.51”, 5.92 lbs.
SunBelt 25
SunBelt 25
High output lamp head with forced air cooling: The lamp head contains a 25” arc length, 10,000W metal halide type lamp, which emits focused UVA, UVB or visible light from its elliptical reflector. Dual integrated cooling blowers ensure long lamp life.Lamp power regulation: The UV curing system’s electronic switch-mode ballast maintains constant lamp power regardless of variations in AC line input or lamp voltages. This regulation provides for repeatable curing times and longer lamp life.Adjustable lamp height: Curing chamber handles and locator pins allow for easy adjustment of lamp height from 2–11”, which provides perfectly repeatable settings of lamp head to belt distance for various part sizes.Full UV shielding: The UV curing conveyor light chamber is totally enclosed, shielding the operator and others from any UV light. The curing chamber entrance and exit are protected by adjustable height light guards that minimize any light leakage.Convenient front-mounted controls and indicator panel: The control panel features lamp enable and emergency-stop switches, AC power, lamp ignited, lamp ready and alarm indicators, as well as a lamp hour meter and USB programming connector.Regulated belt speed controller: A variable frequency drive with digital speed readout is used to adjust and regulate UV conveyor belt speeds up to 58’ per minute, allowing for repeatable product exposure time and curing dose. Exhaust blowers and port: The UV curing chamber has three blowers mounted below the belt for evacuating heat and any product vapors. The outlets of these blowers are ducted to a rear-mounted port for venting to facility exhaust systems. Adjustable mounting feet: The system has four adjustable mounting feet for setting system height and allowing leveling on irregular floor surfaces.In-feed product guides: Dual angled guides at the entrance side of the conveyor’s 33” wide belt ensure that products being cured are directed into the 25” lamp cure zone. For larger products that only require center curing, the guides can be removed.Lamp ballast programming software: The system includes graphical interface software for monitoring curing system performance, diagnosing system alarms and programming lamp output power.SpecificationsSystem TypeConveyor, variable speedPart #UV1655Lamp Power10,000WInput Voltage480VAC ±10% 3 phaseInput Current (Max)13.5 AmpsLamp Intensity2150 mW/cm2 UVA at 2" lamp heightCuring Energy5.0 J/cm2 UVA at 5' /min.Curing Width25" exposure width,33" max part widthBelt Width33"Belt Speed3.0–58' /minLamp Height, Adjustable2–11"Dimensions(L x W x H)100 x 45 x 60"
SunBelt BT9
SunBelt BT9
Adjustable lamp height: The UV conveyor’s adjustable position lamp headrest (sold separately) allows you to repeatedly set the lamp height for an optimum curing distance for various part sizes. The closer the lamp(s) are to the target curing substrate, the higher the effective intensity of UV light will be. The lamp to belt adjustment is 3–6.5” for the PortaRay and 0.5–4” for the SkyRay.Effective UV shielding: The completely enclosed UV curing chamber shields the operator from UV light. The sliding aluminum entry and exit doors are designed to block UV light at the entrance and exit of the conveyor curing chamber. For the further safety of operators, the UV curing chamber shield curtains provide supplemental protection against light scatter from the conveyor entrance and exit when the sliding doors are fixed in the open position to allow the parts to pass.Convenient Side-Mounted Controls and Indicator Panel: A variable frequency drive with digital speed readout adjusts and regulates the conveyor belt speed up to 29’ per minute, allowing for repeatable product exposure time and curing dose. An LED display shows conveyor belt speed in feet per minute, as well as motor subsystem alarm codes. The system features a red emergency stop push-button for power cutoff to the lamps and conveyor motor for emergency shut-off situations, as well as a master AC input power rocker switch with a breaker.Adjustable end chute: An adjustable end chute handles parts as they exit the conveyor system. For accumulating cured parts, you can adjust the chute to a flat horizontal position so the parts slide onto the chute without dropping from the conveyor belt. Alternatively, you can fix the chute in a downward sloping position so processed parts slide onto the benchtop.Removable lamp heads: The conveyor can be outfitted with either one or two PortaRay arc lamp heads, or with a single SkyRay UV LED lamp head. These lamp heads can be easily removed for bulb replacement or maintenance. They can also be moved quickly from the conveyor to an optional low-cost benchtop shielded mounting stand or Rayven UV curing chamber. This feature allows for offline engineering process testing and maximum equipment use.Dual spectrum capable: When configured with two PortaRay lamp heads, the SunBelt BT9 offers the unique curing advantage of mixing any of its four available lamp spectrum types. For instance, the conveyor’s first lamp head can be fitted with a UVB lamp for sealing the surface, preventing oxygen from diffusing and causing surface tackiness. The second lamp can be a UVA type whose longer wavelengths penetrate more effectively, providing deeper curing. This method optimizes adhesive reaction speed without the need for expensive nitrogen purge or the delays of pulse curing.Two AC line input versions: The system is available in voltage ranges that make it compatible for use worldwide. The UV4080 covers the range of 90–132AC, and the UV4081 covers 180–264AC line input.SpecificationsSystem TypeConveyor, variable speedPart Number:UV4080 (120VAC) / UV4081 (240VAC)Lamp PowerPortaRay: 400/600WSkyRay 800: 800WInput Voltage:100–120 / 200–240VAC ± 10%Input Current (Max):20 Amps at 120V / 10 Amps at 240VCuring Energy:0.172–10 J/cm2 (1 PortaRay 400) / 1.12–65 J/cm2 (1 SkyRay 800 365nm)Curing Width:5”Belt Width:9”Belt Speed:0.5 to 29' /minLamp Height, Adjustable:3–6.5” (PortaRay) / 0.5– 4” (SkyRay)Weight:35.1 lbs.Size (L x W x H):30 x 14.56 x 13.36”
HiWatt Arc Lamp Ballast
HiWatt Arc Lamp Ballast
SpecificationsPart #UV1192 (mid pwr),UV1807 (high pwr)Lamp Power2,000–10,000WInput Voltage200–480VAC, 1 or 3 phase (programmable)Input Current (Max)10.5A (UV1192), 15.0A (UV1807)System TypeContinuous mode arc lamp power supplySize/Weight20.11 x 8.32 x 4.54", 25 lbs. (UV1192) 35 lbs. (UV1807)Lamp Output Volts200–850VRMSLow Voltage Outputs24VDC at 1 Amp,3.3VDC at 0.5 AmpsOther FeaturesLamp temp control, USB, RS485, digital I/O signals
SunSpot SM
SunSpot SM
Cool light output: A dichroic-coated reflector reflects only the useable UV wavelengths of light through the light guide. The harmful high-temperature infrared is diverted away from the material being cured. A secondary in-line filter further reduces heat for extremely sensitive applications. Long lamp life: The SunSpot SM UV light curing system provides exceptional lamp life due to several design features:The lamp is mounted vertically, which allows the arc to fall straight in line with gravity. This prevents the arc from wandering into the quartz envelope and overheating it and ensures the arc strikes the conical anode equi-radially, preventing uneven electrode erosion.The lamp is constructed with an extra-heavy blunt-tipped anode electrode, which does not degrade quickly over time (like the needle-shaped electrodes of traditional arc lamps).Airflow is carefully channeled to provide symmetrical cooling of the lamp, which ensures long end seal life and prevents damaging hot spots and arc sputtering.Lamp power regulation: Our patented Power-Plus Lamp Driver maintains constant lamp power regardless of variations in AC line input or lamp voltages. This regulation provides for stable light output, repeatable curing times and longer lamp life.Timer-controlled shutter: An accurate 1–99-second, foot-pedal-controlled exposure timer and shutter free the operator’s hands for other tasks. The timer can be switched from timed to manual mode for operator control of curing duration.Convenient Front Panel Indicators: A front panel hour meter tracks lamp age, allowing for consistent lamp replacement scheduling, and a lamp-ready LED notifies the user when warm-up is complete.Quick-change lamp: The system’s side lamp access panel is easily removed by loosening a single thumbscrew, making lamp or reflector changes possible in as little as one minute.Forced air cooling: The quiet dual-fan cooling system directs air to critical system components, ensuring cool operation and high system reliability.Safety interlocks: Two unique safety interlocks provide maximum protection during operation and maintenance procedures. The first automatically forces the shutter closed if the light guide is removed, preventing operator exposure to high-intensity light. The second immediately removes system AC input power when the lamp access panel is opened, protecting the operator from high voltages or high-intensity light present behind the panel.SpecificationsSystem TypeFocused spot w/ light guidePart #UV0451Lamp Power100WInput Voltage90–265VAC wide range inputInput Current (Max)2 AmpsIrradiance10,000 mW/cm2UVACuring Area1.5"/3.0" spot size at 1.5"/3.0" distanceSize (H x W x D), Weight11.62 x 4.95 x 10.73”, 7.5 lbs.
UV Conveyor 40
UV Conveyor 40
Adjustable lamp height and end chute: Foldaway end covers provide quick access to height adjustment pins, which provide perfectly repeatable settings of lamp head to belt distance. An adjustable position end chute guides accumulating cured parts as they exit the conveyor.Removable lamp heads: The system’s dual lamp heads can be easily removed for bulb replacement and maintenance. They can also be moved quickly from the conveyor to optional low cost shielded mounting stands. This feature allows for offline engineering process testing, and maximum equipment utilization.Dual spectrum capable: The UV Conveyor 40’s dual lamp heads offer the unique curing advantage of mixing any of its four available lamp spectrum types. For instance, the UV conveyor’s first lamp head can be fitted with a UVA type whose longer wavelengths penetrate more effectively, providing deeper UV curing.   The second lamp can be a UVB lamp for sealing the surface, preventing oxygen from diffusing and causing surface tackiness. This optimizes adhesive reaction speed without the need for an expensive nitrogen purge or the delays of pulse curing.Full UV shielding: The conveyor light chamber is totally enclosed, shielding the operator and others nearby from any light exposure during the UV curing process. The light chamber entrance and exit are protected by sliding tinted acrylic doors with extended hoods.Digital speed readout & E-stop switch: A digital rate meter accurately displays the conveyor’s belt speed in feet per minute, allowing for repeatable curing time settings. An emergency stop switch allows quick and safe shutdown of conveyor and lamps.Exhaust port: The light chamber has a top-mounted 3″ diameter port for optional venting to facility exhaust systems.Optional mounting stands: The system may be configured with extruded aluminum height adjustable mounting stands. The stands have unique swivel support brackets that allow them to support inclined conveyors, as well as provide angular transitions between continuous conveyors.Other options: The light chamber can be outfitted with various reflector and lamp spectrum options. Other conveyor lengths are available as special order. Many accessories are also available for configuring the conveyor system into an automated assembly center: Over-belt counter tops, under-belt storage bins, walk-thru gate sections, 90º-turn wheels, end-to-end or end-to-side belt transition plates, product end stops, half stops, guide rails, photoelectric sensors, convenience outlets, remote foot pedals, etc.UV Conveyor 40 (Legacy) - SpecificationsSystem Type:Conveyor, variable speedPart #:UV1052 (120 VAC),UV0887 (240 VAC)Input Voltage:100–120 or 200–240 VAC ±10% rangesInput Current (Max):20A at 120V, 10A at 240VCuring Width:6" exposure width, 9" max part widthBelt Width:9”Belt Speed:0.5–12’ / minLamp Height, Adjustable:1.5–5"Size:54 x 14 x 12”Weight:51 lbs.
Login
Get code
Login
Login
My Profile
0
My Collection
back to the top